flake ice machine F27
FLAKE ICE MACHINE TECHNIQUE PARAMETER | ||||||
Product Quantity (kg/24h) |
Ice Storage (kg) |
Cooling Capacity (kcal/h) |
Total Power (kW) |
Unit Size (Long, wide, high/mm) |
Ice Storage Cabinet Size (Long, wide, high/mm) |
Weight/Kg (No Ice Storage Cabinet) |
350 | 200 | 1961 | 2.4 | 1142*740*760 | 1050*970*900 | 170 |
400 | 300 | 2241 | 2.4 | 1225*740*760 | 1135*1030*1050 | 190 |
500 | 300 | 2801 | 2.4 | 1225*740*760 | 1135*1030*1050 | 190 |
600 | 300 | 3362 | 2.9 | 1225*740*760 | 1135*1030*1050 | 191 |
800 | 300 | 4482 | 3.4 | 1225*740*865 | 1135*1030*1050 | 193 |
1000 | 300 | 5603 | 4.0 | 1225*740*920 | 1135*1030*1050 | 197 |
1200 | 400 | 6724 | 4.8 | 1410*870*920 | 1320*980*1200 | 302 |
1500 | 400 | 8405 | 6.2 | 1410*870*1005 | 1320*980*1200 | 322 |
2000 | 500 | 11206 | 7.7 | 1604*1100*1065 | 1510*1100*1300 | 397 |
2500 | 500 | 13541 | 8.8 | 1610*1100*1305 | 1510*1100*1300 | 491 |
3000 | 500 | 16810 | 11.2 | 1510*1100*1277 | 1510*1100*1300 | 585 |
Product Quantity (kg/24h) |
Ice Storage (kg) |
Cooling Capacity (kcal/h) |
Total Power (kW) |
Unit Size (Long, wide, high/mm) |
Ice Storage Cabinet Size (Long, wide, high/mm) |
Weight/Kg (No Ice Storage Cabinet) |
3000 | 1500 | 16810 | 11.2 | 1510*1100*1277 | 1800*1500*2000 | 585 |
4000 | 2000 | 22413 | 16.2 | 2040*1600*1321 | *Based On The Actual Needs Of Customers | 970 |
5000 | 2000 | 28017 | 18.5 | 2240*1600*1520 | 1070 | |
8000 | 4000 | 44827 | 31.4 | 2700*2018*1525 | 1890 | |
10000 | 5000 | 56034 | 38.2 | 2720*1882*1615 | 1970 | |
12000 | 5000 | 67241 | 38.2 | 2720*1882*1765 | 2030 | |
15000 | 8000 | 84502 | 49.2 | 4440*2224*1936 | 2650 | |
20000 | 10000 | 112068 | 60.9 | 4440*2200*2260 | 3210 | |
25000 | 12000 | 140086 | 75.7 | 4500*2190*2270 | 4500 | |
30000 | 15000 | 168103 | 97.8 | 4500*2320*2462 | 5160 | |
40000 | 20000 | 224137 | 124.3 | 4550*2320*3000 | 5500 | |
50000 | 25000 | 280172 | 147.4 | 4580*2770*3500 | 6300 |
Flake ice temperature: -5C ~ -8C
Flake ice thickness: 1.8mm- 2.5mm
Our flake ice machine use high-performance and low noise compressor.
Used efficient ,energy-saving and green heat exchanger form Europe and American TECH
Compared with the traditional finned condenser,the condenser save 58% refrigerant, reduce 29% energy dissipation,improve 38% heat-exchanging performance, be of high level anti-corrosion, be suit for new refrigerant and meet energy saving and green requests.
Flake ice has dry smooth, not abviours edges thus will not damage the freezer goods, so it
Guarantees the freezer goods’ original favor
Application industries”
Supermarket fresh and hotels chilled
Slaughtering industry
Food processing
Fruit,vegetables distribution and preservation
Concrete mixing works
Pharmaceutical/chemical paint
Flake ice machine structure chart:
General principles of Small-sized Series of Flake ice machine
The following instructions are very helpful to installers. Please contact the Technical Dept. of our company for consultancy by the means on the last page in case of any questions.
Dimension & Parameter Table of Small-sized Series of flake ice machine
Type |
Installation dimensions for the unit including ice storage bin (Length × Width × Height) |
Net unit weight |
Outer dimensions of the unit(Length × Width× Height) |
F050FABL |
1220×950×1650(mm) |
166kg |
1220×950×690 (mm) |
F075FABL |
1220×1050×1915(mm) |
166kg |
1220×870×665(mm) |
F10FABL |
1220×1050×2070(mm) |
208kg |
1220×870×828(mm) |
F12FABL |
1430×975×2515(mm) |
234kg |
1430×975×828(mm) |
F16FABL |
1530×1210×2607(mm) |
336kg |
1530×1210×905(mm) |
F20FABL |
1530×1210×2682(mm) |
348kg |
1530×1210×980(mm) |
F25FABL |
1520×1696×2717(mm) |
398kg |
1530×1210×1040(mm) |
While choosing the installation site and location for all these types of ice machines, the following conditions must be satisfied.
If any of them cannot be satisfied, please choose the installation location anew since forced installation is sure to make the ice machine fail, which doesn’t belong to our company’s warranty scope.
○ The ambient air must be fresh and dustless to prevent the machine from working in excessive moisture;
○ The room temperature must be 5-35℃;
1.The equipment must be kept far from radiators and direct sunshine;
2.The ambient space of the machine must be large enough for air to flow and repairmen to operate in. Please refer to the following table and diagram.
Space Requirements of Small-sized Series of Ice Machines of Self-contained Air-cooling Type | |
a≥500mm | b≥500mm |
c≥1000mm | d≥1000mm |